2008 Livingston OMC Install

DSC_0042.JPG
The Livingston eLIGO coordinator.
DSC_0050.JPG
The now sainted HTRMWA. This object, with 3 drops of methanol, swiped one of the mirrors in the process of going from 80% transmission to 96% transmission.
DSC_0053.JPG
Discussing whether to hang or behead the OMC.
DSC_0057.JPG
A wire and wire clamp in the foreground with the OMC in its frame in the background ready to be hung.
DSC_0062.JPG
Placing the OMC on the lab jacks.
DSC_0063.JPG
Placing the OMC on the lab jacks.
DSC_0066.JPG
The OMC in its frame on the lab jacks in position, ready for EQ stops.
DSC_0069.JPG
Two tip/tilt mode matching mirrors await installation.
DSC_0073.JPG
The OMC in its frame on the lab jacks in position, ready for EQ stops.
DSC_0074.JPG
Hanging OMCs is a messy business, but someone has to do it.
DSC_0082.JPG
The first free hang of the OMC at Livingston.
DSC_0085.JPG
The arrangement of the earthquake stops maximizes clearance for laser beams.
DSC_0091.JPG
The mounting solution for the OMC cables.
DSC_0092.JPG
The two stacks of masses balance the OMC. In between the masses is the wire loom for the auxiliary cables. There are 3 EQ stops visible on the breadboard sides. The back of QPD3 (far field) is visible with the kapton interface sticking out at 45 degrees from vertical. The orange cylinder to the right of the QPD is the 3/4" diameter PZT with a 1/2" curved OMC mirror. To the left of the QPD is the OTAS (thermal actuator).
DSC_0094.JPG
Detail of the PD end of the OMC.
DSC_0097.JPG
Beam's eye view of the input. OMC mirrors 1 and 3 are the one inch optics on tombstones to the left. The view is through two 2 45 degree tombstones onto the near field QPD4. The back of DCPD2 (sees OMC output BS in reflection) is on the right.
DSC_0102.JPG
DCPD1 (sees the OMC output BS in transmission) with EQ stop.
DSC_0111.JPG
DSC_0116.JPG
Mike's the Man.
DSC_0117.JPG
The OMC ready to be installed with EQ stops tightened down.
DSC_0118.JPG
Can I have more porridge?
DSC_0124.JPG
We're not sure why Stefan is in this photo. This shows the beam from the septum to the turning mirror to tip/tilt 1.
DSC_0129.JPG
Rough alignment of the turning mirror in the foreground and TipTilt 1 which is located next to the photographer. The septum is to the left.
DSC_0132.JPG
The electric lift is wheeled into position.
DSC_0137.JPG
OSHA compliant two man lift. No wrists visible thanks to 3XL bunny suits.
DSC_0138.JPG
OMC installation.
DSC_0139.JPG
The OMC immediately after installation.
DSC_0147.JPG
The installed OMC with tip/tilts in the background and foreground. A spare 25 pin cable is coiled on top of the table in the foreground.
DSC_0151.JPG
DSC_0152.JPG
DSC_0153.JPG
The installed OMC looms over the awed spectator