| Pressure Contribution from Flag Hydrocarbons | |||||||||
| 40M Lab RGA Scan Results | |||||||||
| Job # | B22205 | Description: | Micro D Connectors | Date: | 2/22/2005 | ||||
| Oven Used: | B | ||||||||
| AMU 41 | 4.20E-16 | amps | from RGA scan listing | ||||||
| AMU 43 | 6.20E-16 | amps | from RGA scan listing | ||||||
| AMU 53 | 4.60E-17 | amps | from RGA scan listing | ||||||
| AMU 55 | 6.80E-17 | amps | from RGA scan listing | ||||||
| AMU 57 | 4.50E-17 | amps | from RGA scan listing | ||||||
| Sum Flag H/C AMUs | 1.20E-15 | amps | |||||||
| Calib leak rate | 2.00E-08 | torr l/s | (Argon) | ||||||
| AMU 40 (w/leak open) | 2.20E-13 | amps | |||||||
| AMU 40 (background) | 2.20E-14 | amps | |||||||
| Calib leak contributes | 1.98E-13 | amps | = (w/leak open) - (background) | ||||||
| Flag H/C Outgassing | 1.211E-10 | torr l/s | = (Sum Flag H/C AMUs) x (Calib leak rate)/(Calib leak contrib.) | ||||||
| Test item surf area | cm2 | ||||||||
| Normalized outgassing | #DIV/0! | torr l/s-cm2 | = Flag H/C Outgassing/Test item surf area | ||||||
| Full description: | 10 Male and 10 Female GlenAir Micro D Connectors | ||||||||
| Pre-scan bake: | Baked per GlenAir recommended temperature 204C (400F) | ||||||||