Seismic Isolation System Upgrade  SECOND REVIEW

 

18 April, 2003
8:00 am to ~12:00 pm PT

Teleconference:
Participant No.:  610339
Domestic Call In No.:  800-486-2726
Foreign Call In No.:  201-368-8643

 

Design Review Viewgraphs:

Time (PT)

Presenter

PDF

Viewgraphs

PPT

Viewgraphs

Topic

8:00 – 8:10

S. Whitcomb,

D. Coyne

none

none

opening comments, charge to the committee

8:10 – 9:00

J. Giaime

G030228-00.pdf

(0.6MB)

 

Global control issues associated with seismic isolation, an update on the LLO environment (90% percentile) and requirements

9:00 – 9:30

B. Lantz

G030196-00.pdf

(4.0MB)

 

An overview of the EPI system designs and their implementation in prototypes at LASTI

9:30 – 9:40

 

 

 

Break

9:40 – 10:10

B. Lantz

G030227-00.pdf

(3.2MB)

 

Hydraulic External Pre-Isolator (HEPI) Performance

10:10 – 10:40

R. Mittleman,

D. Ottaway

MEPI pdf (2.6MB)

MEPI ppt (3.9MB)

electro-Magnetic External Pre-Isolator (MEPI) Performance

10:40 – 11:10

D. Coyne

G030226-00.pdf (0.6MB)

G030226-03.ppt (1.3MB)

Evaluation of EPI Approaches

11:10 – 11:30

D. Coyne

G030229-00.pdf

(0.4MB)

G030229-00.ppt

(0.3MB)

Cost and Schedule

11:30 – 11:45

S. Whitcomb

none

none

Wrap-up

Photographs of the EPI Hardware:

Photos

Description

Photo1            Photo2            Photo3            Photo4

Photo5            Photo6

MEPI/HAM System including stiffening beam

Photo1            Photo2            Photo3            Photo4

Photo5            Photo6            Photo7            Photo8

Photo9

HEPI/BSC System

Photo1            Photo2            Photo3            Photo4

HEPI Pump Station

Photo1            Photo2            Photo3            Photo4

HEPI Actuator

Design Review Documentation for the 2nd Review:

Number

Title

G030157-00

E. Daw, Results from Analysis of Two Years of Band Limited RMS Monitor Seismic Data

G030126-00

J. Giaime, Piezoelectric Pre-Isolation and Microseism Feedforward for S2

T030073-02

K. Mason, et. al., Structural Modifications

G030187-00.pdf

G030187-00.ppt

L. Zuo, O. Rifai, S. Nayfeh, Modal Analysis and Feedback Control of HAM MEPI

(Note: The modal identification is prior to the structural modifications and the control comments are early comments before much control investigation.)

T030074-01

HEPI vs MEPI

D. Coyne, EPI evaluation

D. DeBra, Comments on the EPI Evaluation

T020077-00

1st Review Committee, Report of the Seismic Retrofit Review Panel

pending

D. Coyne, Response to the Review Committee Report

T030077-00

B. Lantz, C. Hardham, Control and Performance of the HEPI at LASTI

T030079-00

R. Mittleman, D. Ottaway, D. Coyne, MEPI Control Strategies on the HAM Platform

T030023-00

L. Zhang, Optical Contamination Cavity Test Results for Hydraulic Fluids

T030072-00

G. Harry, MEPI Magnetic Field Coupling to Suspensions

M030082-00

EPI Cost Estimate

Relevant Design Review Documentation from the 1st Review:

Number

Title

T020033-02

Initial LIGO Seismic Isolation System Upgrade:
Design Requirements Document

T020050-02

Initial LIGO Seismic Isolation System Upgrade:
Conceptual Design Document

T020040-00

External Seismic Pre-Isolation Retrofit Design                  EPI

T020047-00

Quite Hydraulic Actuators for Initial LIGO                            HEPI

T020041-01

Pre-Isolator with Electromagnetic Actuator                         MEPI

Additional Supporting Documentation:

Number

Title

Hardware Block Diagram

Software Block Diagram

VME Implementation of the EPI System Electronics (block diagram)

pending

Seismic Retrofit Project Schedule

pending

Hydraulic External Pre-Isolator (HEPI) Piping & Instrumentation Drawing

T030034-00

Hydraulic Pump Station: Final Design and Production Proposal

E030100-00, LASTI Drawing List

LASTI pump station drawings

Production pump station layout dwg

Hydraulic Pump Station Drawings

Aquamil (used in LASTI)

Chem-Sol

Chem-Draw

Hydraulic Fluid Data Sheets

Hydraulic EPI, BSC

Hydraulic EPI, HAM

Electro-Magnetic EPI, BSC

Electro-Magnetic EPI, HAM

EPI Spring/Actuator Assembly CAD Images

D020124-02

D020183-00

D020182-00

Electro-Magnetic External Pre-Isolator (MEPI) Top Assembly Drawing

Plan for a Piezoelectric damper

Tuned Mass Damper reference 1

Tuned Mass Damper reference 2

Tuned Dampers for the HAM Stiffening Beam

 

Hydraulic External Pre-Isolator (HEPI) Top Assembly Drawing

Web site

LLO Seismic Time Series Data:

a number of 1500 s data sets of the 9 channels of Streckeisen velocity outputs from LLO.  The goal is to make a "bayou torture test" of ground noise to use as inputs to our retrofit design models and for Advanced LIGO system models.

pending

LHO Seismic Time Series Data:

For windy conditions