FIRST REVIEW

Seismic Isolation System Upgrade

12 April, 2002
9:00 am to 11:35 am PT

 

Design Review Viewgraphs:

File

File Size

Description

G020169-00.pdf

9.5 MB

1st Review Presentation – pdf format

G020169-00.ppt

21.0 MB

1st Review Presentation – ppt format (partial)

 

… or split into pieces:

Time

Presenter

Viewgraphs

Topic

9:00 – 9:10

D. Coyne

0.6MB PDF

Problem scope, introduction

9:10 – 9:30

D. Shoemaker

0.6MB PDF

Requirements

9:30 – 10:00

J. Giaime

1.8MB PDF

External Pre-Isolation

10:00 – 10:25

B. Lantz

5.0MB PDF

Hydraulic actuator (incl. pump station, transmission)

10:25 – 10:30

 

 

Break

10:30 – 10:45

D. Shoemaker

0.5MB PDF

Electromagnetic actuator

10:45 – 11:05

S. Marka

V. Sannibale

1.0MB 1st PDF

0.3MB 2nd PDF

Active Internal Damping

11:05 – 11:25

P. Fritschel,

R. Abbott

0.1MB PDF

Electronics (focus on scope, architecture)

11:25 – 11:35

D. Coyne

0.2MB PDF

Development, Implementation Plan/Schedule

 

Design Review Documentation:

Number

Title

T020033-02

Initial LIGO Seismic Isolation System Upgrade:
Design Requirements Document

T020050-02

Initial LIGO Seismic Isolation System Upgrade:
Conceptual Design Document

T020040-00

External Seismic Pre-Isolation Retrofit Design                  EPI

T020047-00

Quite Hydraulic Actuators for Initial LIGO                            HEPI

T020041-01

Pre-Isolator with Electromagnetic Actuator                         MEPI

T020038-01

Active Internal Stack Damping                                             AID

Additional Supporting Documentation:

Number

Title

T0pending

Electronics for the Hydraulic Pre-Isolator Prototype

M020142-02

Seismic Retrofit Project Schedule

D020214-00

Hydraulic External Pre-Isolator (HEPI) Piping & Instrumentation Drawing

D020209-A

single_frame_pump_station

Hydraulic Pump Station Assembly Plan-view Layout Drawing (preliminary)

Single frame support for the pump station assembly

4_pierwBSC.pdf

Hydraulic External Pre-Isolator (HEPI) Top Assembly Drawing

D020124-02

Hydraulic EPI, BSC

Hydraulic EPI, HAM

Spring/Hydraulic Actuator Assembly Drawing

D020182-00

Electro-Magnetic External Pre-Isolator (MEPI) Top Assembly Drawing

D020183-00

Electromagnetic EPI, HAM

Spring/Electro-Magnetic Actuator Assembly Drawing

D020212-00

Partial 3D CAD view 1

Partial 3D CAD view 2

Active Internal Damping (AID) prototype drawings